Assessment Year | 1995 |
---|---|
Principal Product | Central vacuum systems, bathroom cabinets, intercoms |
NAICS |
n/a
|
SIC | 3635: Household Vacuum Cleaners |
Sales Range | $5 M to 10M |
# of Employees | 60 |
Plant Area |
175,000
ft2
|
Annual Production | 41,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $38,632 | 522,861 |
kWh
|
$0.074 |
Natural Gas | $19,032 | 5,699 |
MMBtu
|
$3.34 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,878 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,039 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $7,455 | $19,000 |
$9,235
124,853
kWh
|
$(-1,780.0)
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,046 | $120 |
$1,046
16,120
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $993 | $437 |
$993
14,361
kWh
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $257 | - |
$257
3,517
kWh
|
- | |
05 | 2.2437: Recover waste heat from equipment | $127 | $201 | - |
$127
-
MMBtu
|
|
TOTAL RECOMMENDED | $9,878 | $19,758 |
$11,531
158,851
kWh
|
$(-1,653.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,039 | $557 |
$2,039
30,481
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs