Assessment Year | 1994 |
---|---|
Principal Product | AC and DC motors |
NAICS |
n/a
|
SIC | 3621: Motors and Generators |
Sales Range | $50 M to 100M |
# of Employees | 498 |
Plant Area |
200,000
ft2
|
Annual Production | 800,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $334,335 | 6,527,843 |
kWh
|
$0.051 |
Natural Gas | $31,573 | 7,713 |
MMBtu
|
$4.09 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,878 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $27,750 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $17,658 | $12,000 |
$24,268
442,849
kWh
|
$(-6,610.0)
-
MMBtu
|
|
02 | 2.7241: Install outside air damper / economizer on hvac unit | $9,302 | - |
$9,302
364,889
kWh
|
- | |
03 | 2.2437: Recover waste heat from equipment | $790 | $1,351 | - |
$790
-
MMBtu
|
|
04 | 2.7224: Reduce space conditioning during non-working hours | $128 | $237 | - |
$128
-
MMBtu
|
|
TOTAL RECOMMENDED | $27,878 | $13,588 |
$33,570
807,738
kWh
|
$(-5,692.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $27,750 | $13,351 |
$33,570
807,738
kWh
|
$(-5,820.0)
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs