Assessment Year | 1994 |
---|---|
Principal Product | Corrugated shipping containers |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 124 |
Plant Area |
139,000
ft2
|
Annual Production | 725,000
thousand feet
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $240,519 | 4,508,793 |
kWh
|
$0.053 |
Natural Gas | $103,502 | 51,912 |
MMBtu
|
$1.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $66,928 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,205 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,233 | $8,800 |
$9,233
138,921
kWh
|
- | |
02 | 2.2511: Insulate bare equipment | $505 | $526 | - |
$505
-
MMBtu
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,645 | - |
$1,645
29,308
kWh
|
- | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $9,581 | $2,618 | - |
$9,581
-
MMBtu
|
|
05 | 2.2437: Recover waste heat from equipment | $1,652 | $832 | - |
$1,652
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $815 | $2,199 |
$815
4,689
kWh
|
- | |
07 | 2.7232: Replace existing hvac unit with high efficiency model | $43,497 | $198,000 |
$43,497
567,116
kWh
|
- | |
TOTAL RECOMMENDED | $66,928 | $212,975 |
$55,190
740,034
kWh
|
$11,738
-
MMBtu
|
||
TOTAL IMPLEMENTED | $12,205 | $12,357 |
$10,048
143,610
kWh
|
$2,157
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs