Assessment Year | 1994 |
---|---|
Principal Product | Tempered glass |
NAICS |
n/a
|
SIC | 3211: Flat Glass |
Sales Range | $5 M to 10M |
# of Employees | 80 |
Plant Area |
60,000
ft2
|
Annual Production | 2,815
thousand feet
|
Production Hrs. Annual | 7,836
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $144,816 | 3,050,703 |
kWh
|
$0.047 |
Natural Gas | $1,911 | 383 |
MMBtu
|
$4.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $39,857 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,339 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $30,276 | $72,252 |
$30,276
670,574
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,448 | $13,180 |
$2,448
4,982
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,944 | $60 |
$1,944
44,549
kWh
|
|
04 | 2.4133: Use most efficient type of electric motors | $1,821 | $4,532 |
$1,821
28,722
kWh
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,809 | - |
$1,809
28,722
kWh
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $757 | $714 |
$757
12,016
kWh
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $638 | $1,443 |
$638
5,569
kWh
|
|
08 | 2.7135: Install occupancy sensors | $164 | $190 |
$164
3,517
kWh
|
|
TOTAL RECOMMENDED | $39,857 | $92,371 |
$39,857
798,651
kWh
|
||
TOTAL IMPLEMENTED | $3,339 | $2,217 |
$3,339
62,134
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |