| Assessment Year | 1994 |
|---|---|
| Principal Product | Fixtures and furniture |
| NAICS |
n/a
|
| SIC | 2521: Wood Office Furniture |
| Sales Range | $10 M to 50M |
| # of Employees | 300 |
| Plant Area |
80,000
ft2
|
| Annual Production | 16,000
pieces
|
| Production Hrs. Annual | 6,816
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $87,311 | 1,664,127 |
kWh
|
$0.052 |
| Natural Gas | $25,336 | 8,424 |
MMBtu
|
$3.01 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,267 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,654 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,568 | $4,848 |
$1,568
17,585
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,701 | $12,214 |
$3,701
46,893
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $187 | $200 |
$187
4,982
kWh
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $665 | $851 |
$665
17,585
kWh
|
- | |
| 05 | 2.2437: Recover waste heat from equipment | $1,114 | $800 | - |
$1,114
-
MMBtu
|
|
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $766 | - |
$766
24,033
kWh
|
- | |
| 07 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $1,266 | $3,750 |
$1,266
33,411
kWh
|
- | |
| TOTAL RECOMMENDED | $9,267 | $22,663 |
$8,153
144,489
kWh
|
$1,114
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,654 | $12,414 |
$4,654
75,908
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs