| Assessment Year | 1994 |
|---|---|
| Principal Product | Processed peanuts |
| NAICS |
n/a
|
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 230 |
| Plant Area |
216,246
ft2
|
| Annual Production | 90,000
ton
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $438,023 | 6,485,639 |
kWh
|
$0.068 |
| Natural Gas | $15,905 | 3,202 |
MMBtu
|
$4.97 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $34,531 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $32,923 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7134: Use photocell controls | $2,392 | - |
$2,392
34,291
kWh
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $9,437 | $16,090 |
$9,437
134,818
kWh
|
|
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,975 | $5,400 |
$2,975
42,497
kWh
|
|
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,305 | $68,590 |
$17,305
247,362
kWh
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $97 | - |
$97
1,465
kWh
|
|
| 06 | 2.2437: Recover waste heat from equipment | $717 | $2,000 |
$717
42,790
kWh
|
|
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,608 | $2,530 |
$1,608
19,930
kWh
|
|
| TOTAL RECOMMENDED | $34,531 | $94,610 |
$34,531
523,153
kWh
|
||
| TOTAL IMPLEMENTED | $32,923 | $92,080 |
$32,923
503,223
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs