Assessment Year | 1994 |
---|---|
Principal Product | Processed peanuts |
NAICS |
n/a
|
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $50 M to 100M |
# of Employees | 230 |
Plant Area |
216,246
ft2
|
Annual Production | 90,000
ton
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $438,023 | 6,485,639 |
kWh
|
$0.068 |
Natural Gas | $15,905 | 3,202 |
MMBtu
|
$4.97 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,531 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,923 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7134: Use photocell controls | $2,392 | - |
$2,392
34,291
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $9,437 | $16,090 |
$9,437
134,818
kWh
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,975 | $5,400 |
$2,975
42,497
kWh
|
|
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,305 | $68,590 |
$17,305
247,362
kWh
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $97 | - |
$97
1,465
kWh
|
|
06 | 2.2437: Recover waste heat from equipment | $717 | $2,000 |
$717
42,790
kWh
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,608 | $2,530 |
$1,608
19,930
kWh
|
|
TOTAL RECOMMENDED | $34,531 | $94,610 |
$34,531
523,153
kWh
|
||
TOTAL IMPLEMENTED | $32,923 | $92,080 |
$32,923
503,223
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs