| Assessment Year | 1993 |
|---|---|
| Principal Product | Wood Products, Printing |
| NAICS |
n/a
|
| SIC | 2499: Wood Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 110 |
| Plant Area |
72,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $19,835 | 224,795 |
kWh
|
$0.088 |
| Natural Gas | $10,498 | 2,449 |
MMBtu
|
$4.29 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,566 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7132: Install timers on light switches in little used areas | $4,051 | $1,350 | n/a | - |
$4,051
-
MMBtu
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,870 | $8,403 | n/a |
$1,870
21,395
kWh
|
- |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,411 | $3,977 | n/a |
$1,411
15,240
kWh
|
- |
| 04 | 2.2511: Insulate bare equipment | $201 | $361 | n/a | - |
$201
-
MMBtu
|
| 05 | 2.4239: Eliminate or reduce compressed air usage | $33 | $346 | n/a |
$33
293
kWh
|
- |
| TOTAL RECOMMENDED | $7,566 | $14,437 |
$3,314
36,928
kWh
|
$4,252
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs