Assessment Year | 1993 |
---|---|
Principal Product | Water Pumps |
NAICS |
n/a
|
SIC | 3561: Pumps and Pumping Equipment |
Sales Range | $50 M to 100M |
# of Employees | 350 |
Plant Area |
117,700
ft2
|
Annual Production | 1,900,000
pieces
|
Production Hrs. Annual | 6,696
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $154,511 | 2,717,175 |
kWh
|
$0.057 |
Natural Gas | $55,099 | 16,671 |
MMBtu
|
$3.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,217 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,446 | $1,961 |
$3,446
54,220
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,314 | $753 |
$1,314
14,654
kWh
|
- | |
03 | 2.2511: Insulate bare equipment | $1,668 | $3,528 | - |
$1,668
-
MMBtu
|
|
04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $2,789 | $9,000 |
$2,789
79,132
kWh
|
- | |
TOTAL RECOMMENDED | $9,217 | $15,242 |
$7,549
148,006
kWh
|
$1,668
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs