Assessment Year | 1993 |
---|---|
Principal Product | Portland Cement, Low Alkali, and Mas |
NAICS |
n/a
|
SIC | 3241: Cement, Hydraulic |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
15,000
ft2
|
Annual Production | 600,000
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,728,226 | 78,798,360 |
kWh
|
$0.035 |
Natural Gas | $339,593 | 158,522 |
MMBtu
|
$2.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $171,268 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $156,285 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $53,433 | $110,746 |
$53,433
1,526,671
kWh
|
|
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $102,852 | $309,735 |
$102,852
2,938,746
kWh
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $14,983 | $30,075 |
$14,983
428,195
kWh
|
|
TOTAL RECOMMENDED | $171,268 | $450,556 |
$171,268
4,893,612
kWh
|
||
TOTAL IMPLEMENTED | $156,285 | $420,481 |
$156,285
4,465,417
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs