Assessment Year | 1991 |
---|---|
Principal Product | COOKIES |
NAICS |
n/a
|
SIC | 2052: Cookies and Crackers |
Sales Range | $10 M to 50M |
# of Employees | 366 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $127,303 | 2,194,900 |
kWh
|
$0.058 |
Natural Gas | $140,044 | 55,417 |
MMBtu
|
$2.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,748 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,748 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $191 | $453 |
$191
4,396
kWh
|
- | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $439 | - |
$439
9,379
kWh
|
- | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $567 | - |
$567
11,723
kWh
|
- | - | |
04 | 2.2511: Insulate bare equipment | $441 | $473 | - |
$441
-
MMBtu
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,215 | - |
$1,345
28,722
kWh
|
- | $(-130.0) | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,858 | - |
$4,411
76,202
kWh
|
- | $(-553.0) | |
07 | 2.3212: Optimize plant power factor | $7,037 | $4,975 |
$7,037
-
kWh
|
- | - | |
TOTAL RECOMMENDED | $13,748 | $5,901 |
$13,990
130,422
kWh
|
$441
-
MMBtu
|
$(-683.0) | ||
TOTAL IMPLEMENTED | $13,748 | $5,901 |
$13,990
130,422
kWh
|
$441
-
MMBtu
|
$(-683.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs