Assessment Year | 1991 |
---|---|
Principal Product | GLASS CONTAINERS |
NAICS |
n/a
|
SIC | 3221: Glass Containers |
Sales Range | $50 M to 100M |
# of Employees | 380 |
Plant Area |
n/a
|
Annual Production | 191,000
ton
|
Production Hrs. Annual | 8,640
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $857,320 | 53,495,311 |
kWh
|
$0.016 |
Natural Gas | $2,027,134 | 1,204,479 |
MMBtu
|
$1.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $144,787 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $144,787 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $131,560 | $248,667 |
$131,560
5,348,183
kWh
|
- | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,008 | $4,500 |
$4,008
122,216
kWh
|
- | - | |
03 | 2.2425: Use flue gases to heat process or service water | $3,564 | $13,345 |
$(-53.0)
(-2,052)
kWh
|
$3,617
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $264 | $519 |
$264
9,379
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,391 | - |
$3,891
116,061
kWh
|
- | $1,500 | |
TOTAL RECOMMENDED | $144,787 | $267,031 |
$139,670
5,593,787
kWh
|
$3,617
-
MMBtu
|
$1,500 | ||
TOTAL IMPLEMENTED | $144,787 | $267,031 |
$139,670
5,593,787
kWh
|
$3,617
-
MMBtu
|
$1,500 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs