Assessment Year | 1989 |
---|---|
Principal Product | AEROSPACE STRUCTURES |
NAICS |
n/a
|
SIC | 3761: Guided Missiles and Space Vehicles |
Sales Range | $10 M to 50M |
# of Employees | 220 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $221,059 | 4,953,986 |
kWh
|
$0.045 |
Natural Gas | $30,981 | 7,447 |
MMBtu
|
$4.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $42,674 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,497 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3511: Use plant owned transformers or lease transformers | $17,721 | $47,000 |
$17,721
-
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,462 | $20,683 |
$9,772
259,086
kWh
|
$(-2,100.0)
-
MMBtu
|
$(-2,210.0) | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $5,039 | - |
$5,664
-
kWh
|
- | $(-625.0) | |
04 | 2.7226: Use computer programs to optimize hvac performance | $5,013 | $600 |
$5,013
179,074
kWh
|
- | - | |
05 | 2.7123: Keep lamps and reflectors clean | $3,684 | $11,700 |
$3,803
74,150
kWh
|
$(-600.0)
-
MMBtu
|
$481 | |
06 | 2.7314: Reduce ventilation air | $2,677 | $650 |
$2,677
47,479
kWh
|
- | - | |
07 | 2.2437: Recover waste heat from equipment | $1,620 | $980 | - |
$1,620
-
MMBtu
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,310 | $3,106 |
$1,310
31,360
kWh
|
- | - | |
09 | 2.4239: Eliminate or reduce compressed air usage | $148 | $270 |
$148
5,275
kWh
|
- | - | |
TOTAL RECOMMENDED | $42,674 | $84,989 |
$46,108
596,424
kWh
|
$(-1,080.0)
-
MMBtu
|
$(-2,354.0) | ||
TOTAL IMPLEMENTED | $14,497 | $2,500 |
$13,502
231,828
kWh
|
$1,620
-
MMBtu
|
$(-625.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs