| Assessment Year | 1989 |
|---|---|
| Principal Product | PORK & BEEF |
| NAICS |
n/a
|
| SIC | 2011: Meat Packing Plants |
| Sales Range | $10 M to 50M |
| # of Employees | 70 |
| Plant Area |
n/a
|
| Annual Production | 8,500,000
lb
|
| Production Hrs. Annual | 3,600
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $100,521 | 2,034,877 |
kWh
|
$0.049 |
| Natural Gas | $36,093 | 12,414 |
MMBtu
|
$2.91 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,543 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,776 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $2,160 | $5,523 |
$(-147.0)
(-2,931)
kWh
|
$2,307
-
MMBtu
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,738 | $1,478 |
$3,607
69,168
kWh
|
- | $131 | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $233 | $123 |
$233
4,103
kWh
|
- | - | |
| 04 | 2.3212: Optimize plant power factor | $1,607 | $2,500 |
$1,607
-
kWh
|
- | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,788 | - |
$2,788
64,478
kWh
|
- | - | |
| 06 | 2.2136: Install / repair insulation on steam lines | $1,017 | $2,289 | - |
$1,017
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $11,543 | $11,913 |
$8,088
134,818
kWh
|
$3,324
-
MMBtu
|
$131 | ||
| TOTAL IMPLEMENTED | $7,776 | $3,890 |
$6,628
137,749
kWh
|
$1,017
-
MMBtu
|
$131 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs