Assessment Year | 1989 |
---|---|
Principal Product | BOOK DEPOSIT BOXES |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 85 |
Plant Area |
n/a
|
Annual Production | 50
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $64,032 | 1,173,505 |
kWh
|
$0.055 |
Natural Gas | $15,977 | 4,986 |
MMBtu
|
$3.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,263 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,263 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,120 | $5,685 |
$5,436
95,838
kWh
|
$(-316.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $771 | $1,425 |
$659
11,430
kWh
|
$112 | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $156 | - |
$156
2,931
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $180 | $155 |
$180
2,931
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $542 | $1,336 |
$542
10,844
kWh
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $494 | - |
$644
19,050
kWh
|
$(-150.0) | |
TOTAL RECOMMENDED | $7,263 | $8,601 |
$7,617
143,024
kWh
|
$(-354.0) | ||
TOTAL IMPLEMENTED | $7,263 | $8,601 |
$7,617
143,024
kWh
|
$(-354.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs