Assessment Year | 1989 |
---|---|
Principal Product | WALLBOARD & PLASTER |
NAICS |
n/a
|
SIC | 3275: Gypsum Products |
Sales Range | $10 M to 50M |
# of Employees | 275 |
Plant Area |
n/a
|
Annual Production | 565,000
ton
|
Production Hrs. Annual | 8,640
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $713,457 | 31,375,147 |
kWh
|
$0.023 |
Natural Gas | $1,511,833 | 687,197 |
MMBtu
|
$2.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $106,340 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $106,340 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $73,916 | $54,162 |
$73,916
2,012,310
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,139 | $4,563 |
$15,139
412,075
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $12,641 | $11,362 |
$12,641
330,598
kWh
|
- | |
04 | 2.2511: Insulate bare equipment | $3,121 | $6,944 | - |
$3,121
-
MMBtu
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,523 | $704 |
$1,523
41,618
kWh
|
- | |
TOTAL RECOMMENDED | $106,340 | $77,735 |
$103,219
2,796,601
kWh
|
$3,121
-
MMBtu
|
||
TOTAL IMPLEMENTED | $106,340 | $77,735 |
$103,219
2,796,601
kWh
|
$3,121
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs