| Assessment Year | 1989 |
|---|---|
| Principal Product | TIRE CARE PRODUCTS |
| NAICS |
n/a
|
| SIC | 3011: Tires and Inner Tubes |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
n/a
|
| Annual Production | 120,000
pieces
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $115,601 | 2,266,706 |
kWh
|
$0.051 |
| Natural Gas | $50,391 | 17,869 |
MMBtu
|
$2.82 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,736 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,622 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $803 | $671 |
$803
17,585
kWh
|
- | |
| 02 | 2.2122: Install / repair insulation on condensate lines | $155 | $208 | - |
$155
-
MMBtu
|
|
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,624 | $1,500 | - |
$1,624
-
MMBtu
|
|
| 04 | 2.2113: Repair or replace steam traps | $6,091 | $7,500 | - |
$6,091
-
MMBtu
|
|
| 05 | 2.2515: Use optimum thickness insulation | $959 | $1,320 |
$959
31,946
kWh
|
- | |
| 06 | 2.4133: Use most efficient type of electric motors | $104 | $222 |
$104
2,052
kWh
|
- | |
| TOTAL RECOMMENDED | $9,736 | $11,421 |
$1,866
51,583
kWh
|
$7,870
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $8,622 | $9,893 |
$907
19,637
kWh
|
$7,715
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs