| Assessment Year | 1988 |
|---|---|
| Principal Product | METAL FURNITURE |
| NAICS |
n/a
|
| SIC | 2514: Metal Household Furniture |
| Sales Range | $5 M to 10M |
| # of Employees | 110 |
| Plant Area |
n/a
|
| Annual Production | 425,000
pieces
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $85,915 | 1,194,607 |
kWh
|
$0.072 |
| Natural Gas | $107,783 | 33,435 |
MMBtu
|
$3.22 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,803 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,272 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $408 | $249 |
$408
7,327
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,185 | $3,399 |
$1,185
16,706
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $146 | $351 |
$146
2,638
kWh
|
- | - | |
| 04 | 2.7221: Lower temperature during the winter season and vice-versa | $1,977 | $600 |
$1,977
35,170
kWh
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $743 | - |
$843
14,947
kWh
|
- | $(-100.0) | |
| 06 | 2.7231: Use radiant heater for spot heating | $3,249 | $3,150 | - |
$3,249
-
MMBtu
|
- | |
| 07 | 2.4133: Use most efficient type of electric motors | $95 | $287 |
$95
1,758
kWh
|
- | - | |
| TOTAL RECOMMENDED | $7,803 | $8,036 |
$4,654
78,546
kWh
|
$3,249
-
MMBtu
|
$(-100.0) | ||
| TOTAL IMPLEMENTED | $5,272 | $6,836 |
$2,123
33,411
kWh
|
$3,249
-
MMBtu
|
$(-100.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs