Assessment Year | 1987 |
---|---|
Principal Product | CENTRAL VACUUM SYSTEMS |
NAICS |
n/a
|
SIC | 3589: Service Industry Machinery, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 60 |
Plant Area |
n/a
|
Annual Production | 22,500
pieces
|
Production Hrs. Annual | 4,992
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $40,132 | 570,926 |
kWh
|
$0.070 |
Natural Gas | $25,339 | 6,290 |
MMBtu
|
$4.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,522 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,734 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $6,433 | $3,500 | - |
$6,433
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $520 | $120 |
$520
6,448
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $268 | - |
$318
5,569
kWh
|
- | $(-50.0) | |
04 | 2.2511: Insulate bare equipment | $626 | $216 |
$626
11,137
kWh
|
- | - | |
05 | 2.2511: Insulate bare equipment | $162 | $400 | - |
$162
-
MMBtu
|
- | |
06 | 2.2437: Recover waste heat from equipment | $513 | $305 |
$513
25,498
kWh
|
- | - | |
TOTAL RECOMMENDED | $8,522 | $4,541 |
$1,977
48,652
kWh
|
$6,595
-
MMBtu
|
$(-50.0) | ||
TOTAL IMPLEMENTED | $7,734 | $3,925 |
$1,351
37,515
kWh
|
$6,433
-
MMBtu
|
$(-50.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs