| Assessment Year | 2018 |
|---|---|
| Principal Product | Digital Publishing Magazines |
| NAICS | 323111: Commercial Printing (except Screen and Books) |
| SIC | 2754: Commercial Printing, Gravure |
| Sales Range | $100 M to 500M |
| # of Employees | 25 |
| Plant Area |
578,000
ft2
|
| Annual Production | 12,000,000
units
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $454,347 | 9,251,600 |
kWh
|
$0.049 | |
| Electricity Demand | $107,403 | 23,270 |
kW-mo/yr
|
$4.62 | |
| Electricity Fees | $51,173 | - |
|
- | |
| Natural Gas | $33,649 | 5,281 |
MMBtu
|
$6.37 | |
| Waste Disposal Costs | |||||
| Water Usage | $96,079 | 8,408 |
Tgal
|
$11.43 | |
| TOTAL YEARLY COSTS | $742,651 | ||||
| RECOMMENDED SAVINGS* | $32,199 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $29,415 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,615 | $60,000 |
$12,784
260,600
kWh
|
$3,831
-
kW-mo/yr
|
- | - | - | |
| 02 | 3.4116: Meter recycled water (to reduce sewer charges) | $12,800 | $2,000 | - | - | - | - |
$12,800
-
Tgal
|
|
| 03 | 3.4156: Use flow control valves on equipment to optimize water use | $2,784 | $275 | - | - |
$600
-
MMBtu
|
$2,184
-
Tgal
|
- | |
| TOTAL RECOMMENDED | $32,199 | $62,275 |
$12,784
260,600
kWh
|
$3,831
-
kW-mo/yr
|
$600
-
MMBtu
|
$2,184
-
Tgal
|
$12,800
-
Tgal
|
||
| TOTAL IMPLEMENTED | $29,415 | $62,000 |
$12,784
260,600
kWh
|
$3,831
-
kW-mo/yr
|
- | - |
$12,800
-
Tgal
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs