| Assessment Year | 1987 |
|---|---|
| Principal Product | AUDIO VISUAL FURNITURE & EQUIPMENT |
| NAICS |
n/a
|
| SIC | 2531: Public Building and Related Furniture |
| Sales Range | $1 M to 5M |
| # of Employees | 50 |
| Plant Area |
n/a
|
| Annual Production | 30,000
pieces
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $69,177 | 710,141 |
kWh
|
$0.097 |
| Natural Gas | $36,464 | 10,538 |
MMBtu
|
$3.46 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,774 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,742 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,153 | $9,288 |
$5,153
50,410
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $884 | $270 |
$884
6,741
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $388 | $573 |
$388
3,224
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $179 | $225 |
$179
1,465
kWh
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $153 | $93 |
$153
879
kWh
|
- | |
| 06 | 2.4133: Use most efficient type of electric motors | $138 | $126 |
$138
1,465
kWh
|
- | |
| 07 | 2.4322: Use or replace with energy efficient substitutes | $1,879 | $3,360 |
$(-14,314.0)
(-140,387)
kWh
|
$16,193
-
MMBtu
|
|
| TOTAL RECOMMENDED | $8,774 | $13,935 |
$(-7,419.0)
(-76,203)
kWh
|
$16,193
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,742 | $1,287 |
$1,742
13,774
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs