Assessment Year | 1986 |
---|---|
Principal Product | STEEL FABRIC.FITTINGS |
NAICS |
n/a
|
SIC | 3398: Metal Heat Treating |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $48,029 | 699,004 |
kWh
|
$0.069 |
Natural Gas | $20,949 | 4,769 |
MMBtu
|
$4.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,015 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $999 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $361 | $39 |
$361
6,155
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $564 | - |
$644
10,844
kWh
|
- | $(-80.0) | |
03 | 2.7231: Use radiant heater for spot heating | $7,928 | $18,000 | - |
$7,928
-
MMBtu
|
- | |
04 | 2.4322: Use or replace with energy efficient substitutes | $74 | $50 |
$74
1,172
kWh
|
- | - | |
05 | 2.2514: Cover open tanks | $88 | $133 | - |
$88
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $9,015 | $18,222 |
$1,079
18,171
kWh
|
$8,016
-
MMBtu
|
$(-80.0) | ||
TOTAL IMPLEMENTED | $999 | $89 |
$1,079
18,171
kWh
|
- | $(-80.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs