Assessment Year | 1986 |
---|---|
Principal Product | IRON CASTINGS |
NAICS |
n/a
|
SIC | 3321: Gray and Ductile Iron Foundries |
Sales Range | $5 M to 10M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 2,500
ton
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $208,742 | 5,711,899 |
kWh
|
$0.037 |
Natural Gas | $20,193 | 5,216 |
MMBtu
|
$3.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,877 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,214 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,521 | - |
$2,631
82,356
kWh
|
- | $(-110.0) | |
02 | 2.4133: Use most efficient type of electric motors | $693 | $1,821 |
$693
21,981
kWh
|
- | - | |
03 | 2.7231: Use radiant heater for spot heating | $7,663 | $36,000 | - |
$7,663
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $10,877 | $37,821 |
$3,324
104,337
kWh
|
$7,663
-
MMBtu
|
$(-110.0) | ||
TOTAL IMPLEMENTED | $3,214 | $1,821 |
$3,324
104,337
kWh
|
- | $(-110.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs