| Assessment Year | 1986 |
|---|---|
| Principal Product | OILFIELD EQUIPMENT |
| NAICS |
n/a
|
| SIC | 3533: Oil and Gas Field Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 110 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $85,179 | 1,511,137 |
kWh
|
$0.056 |
| Natural Gas | $4,293 | 964 |
MMBtu
|
$4.45 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,988 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,588 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $643 | - |
$643
15,826
kWh
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $721 | $200 |
$721
26,377
kWh
|
- | |
| 03 | 2.2511: Insulate bare equipment | $224 | $92 |
$224
8,206
kWh
|
- | |
| 04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $349 | $510 |
$349
-
kWh
|
- | |
| 05 | 2.7231: Use radiant heater for spot heating | $2,051 | $7,950 | - |
$2,051
-
MMBtu
|
|
| TOTAL RECOMMENDED | $3,988 | $8,752 |
$1,937
50,409
kWh
|
$2,051
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,588 | $292 |
$1,588
50,409
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs