| Assessment Year | 1985 |
|---|---|
| Principal Product | MOBILE HOME SKIRTING |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | less than $500 k |
| # of Employees | 14 |
| Plant Area |
n/a
|
| Annual Production | 350
thousand feet
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $10,634 | 142,145 |
kWh
|
$0.075 |
| Natural Gas | $830 | 188 |
MMBtu
|
$4.41 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $753 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $753 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $428 | $650 | - |
$428
-
MMBtu
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $45 | $12 |
$45
879
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $191 | $240 |
$191
3,517
kWh
|
- | |
| 04 | 2.7229: Air condition only space necessary | $71 | $145 | - |
$71
-
MMBtu
|
|
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18 | $60 |
$18
293
kWh
|
- | |
| TOTAL RECOMMENDED | $753 | $1,107 |
$254
4,689
kWh
|
$499
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $753 | $1,107 |
$254
4,689
kWh
|
$499
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs