Assessment Year | 1984 |
---|---|
Principal Product | LINEN SERVICE |
NAICS |
n/a
|
SIC | 3582: Commercial Laundry, Drycleaning, and Pressing Machines |
Sales Range | $1 M to 5M |
# of Employees | 150 |
Plant Area |
n/a
|
Annual Production | 6,250,000
lb
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $57,325 | 1,082,063 |
kWh
|
$0.053 |
Natural Gas | $103,668 | 27,657 |
MMBtu
|
$3.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,301 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,108 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $320 | $450 | - |
$330
-
MMBtu
|
$(-10.0) | |
02 | 2.4322: Use or replace with energy efficient substitutes | $140 | - |
$140
4,103
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $45 | $60 |
$45
1,172
kWh
|
- | - | |
04 | 2.2135: Repair and eliminate steam leaks | $1,250 | $180 | - |
$1,250
-
MMBtu
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $745 | $122 |
$745
15,240
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,460 | $1,350 |
$1,460
27,843
kWh
|
- | - | |
07 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $60 | $50 |
$60
1,758
kWh
|
- | - | |
08 | 2.7111: Reduce illumination to minimum necessary levels | $355 | $80 |
$355
6,741
kWh
|
- | - | |
09 | 2.2511: Insulate bare equipment | $103 | $84 | - |
$103
-
MMBtu
|
- | |
10 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $563 | $116 | - |
$563
-
MMBtu
|
- | |
11 | 2.2511: Insulate bare equipment | $113 | $310 | - |
$113
-
MMBtu
|
- | |
12 | 2.3191: Use demand controller or load shedder | $105 | - |
$105
-
kWh
|
- | - | |
13 | 2.4221: Install compressor air intakes in coolest locations | $42 | $127 |
$42
1,172
kWh
|
- | - | |
TOTAL RECOMMENDED | $5,301 | $2,929 |
$2,952
58,029
kWh
|
$2,359
-
MMBtu
|
$(-10.0) | ||
TOTAL IMPLEMENTED | $2,108 | $891 |
$642
14,946
kWh
|
$1,466
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs