| Assessment Year | 1983 |
|---|---|
| Principal Product | FRESH WATER MARINAS |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 60 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $14,154 | 240,035 |
kWh
|
$0.059 |
| Natural Gas | $41,657 | 9,352 |
MMBtu
|
$4.45 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $2,461 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $823 | $1,750 | - |
$823
-
MMBtu
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $860 | $1,238 |
$860
14,947
kWh
|
- | |
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $420 | $300 | - |
$420
-
MMBtu
|
|
| 04 | 2.2136: Install / repair insulation on steam lines | $358 | $262 | - |
$358
-
MMBtu
|
|
| TOTAL RECOMMENDED | $2,461 | $3,550 |
$860
14,947
kWh
|
$1,601
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs