Assessment Year | 1982 |
---|---|
Principal Product | BRICKS |
NAICS |
n/a
|
SIC | 3251: Brick and Structural Clay Tile |
Sales Range | $5 M to 10M |
# of Employees | 45 |
Plant Area |
n/a
|
Annual Production | 36,000,000
pieces
|
Production Hrs. Annual | 1,600
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $106,034 | 2,772,274 |
kWh
|
$0.038 |
Natural Gas | $355,950 | 139,350 |
MMBtu
|
$2.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,901 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $73 | $44 |
$73
2,052
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $128 | - |
$128
3,224
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $245 | $3,210 |
$245
6,448
kWh
|
- | |
04 | 2.2424: Use heat in flue gases to preheat products or materials | $13,455 | $2,500 | - |
$13,455
-
MMBtu
|
|
TOTAL RECOMMENDED | $13,901 | $5,754 |
$446
11,724
kWh
|
$13,455
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs