| Assessment Year | 2000 |
|---|---|
| Principal Product | Copper Plumbing Fittings |
| NAICS |
n/a
|
| SIC | 3366: Copper Foundries |
| Sales Range | $10 M to 50M |
| # of Employees | 300 |
| Plant Area |
217,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $912,337 | 37,150,352 |
kWh
|
$0.025 |
| Electricity Demand | $287,797 | 68,544 |
kW-mo/yr
|
$4.20 |
| Electricity Fees | $260,235 | - |
|
- |
| LPG | $359,404 | 97,107 |
MMBtu
|
$3.70 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $39,017 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,013 | $8,525 | n/a |
$1,932
78,253
kWh
|
$1,081
-
kW-mo/yr
|
- | - |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,297 | $520 | n/a |
$2,297
92,907
kWh
|
- | - | - |
| 03 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $13,669 | $113,000 | n/a | - | - | $13,669 | - |
| 04 | 3.4155: Meter waste water | $20,038 | $6,955 | n/a | - | - | - | $20,038 |
| TOTAL RECOMMENDED | $39,017 | $129,000 |
$4,229
171,160
kWh
|
$1,081
-
kW-mo/yr
|
$13,669 | $20,038 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs