Assessment Year | 2000 |
---|---|
Principal Product | Finished, Printed and Laminated Wall Panels and Cut to Size |
NAICS |
n/a
|
SIC | 2435: Hardwood Veneer and Plywood |
Sales Range | $100 M to 500M |
# of Employees | 170 |
Plant Area |
4,286,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,625
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $198,276 | 7,437,866 |
kWh
|
$0.027 |
Electricity Demand | $78,661 | 33,600 |
kW-mo/yr
|
$2.34 |
Electricity Fees | $2,935 | - |
|
- |
Natural Gas | $197,934 | 13,878 |
MMBtu
|
$14.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $54,544 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $36,345 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,895 | $103,963 |
$12,750
477,726
kWh
|
$1,145
-
kW-mo/yr
|
- | |
02 | 2.7144: Install spectral reflectors / delamp | $2,597 | $560 |
$2,385
89,390
kWh
|
$212
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,019 | $400 |
$3,019
112,837
kWh
|
- | - | |
04 | 2.7135: Install occupancy sensors | $1,285 | $760 |
$1,285
48,066
kWh
|
- | - | |
05 | 4.211: Consider use / purchase of bulk materials where possible | $31,722 | - | - | - |
$31,722
-
MMBtu
|
|
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,026 | $2,400 | - | - |
$2,026
-
MMBtu
|
|
TOTAL RECOMMENDED | $54,544 | $108,083 |
$19,439
728,019
kWh
|
$1,357
-
kW-mo/yr
|
$33,748
-
MMBtu
|
||
TOTAL IMPLEMENTED | $36,345 | $2,960 |
$2,385
89,390
kWh
|
$212
-
kW-mo/yr
|
$33,748
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs