Assessment Year | 2000 |
---|---|
Principal Product | Printing Blankets |
NAICS |
n/a
|
SIC | 2822: Synthetic Rubber (Vulcanizable Elastomers) |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
16,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $150,064 | 4,052,169 |
kWh
|
$0.037 |
Electricity Demand | $37,966 | - |
|
- |
Electricity Fees | $3,783 | - |
|
- |
Natural Gas | $141,551 | 44,279 |
MMBtu
|
$3.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,486 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,642 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,590 | $42,582 |
$6,334
172,040
kWh
|
$1,256
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $2,327 | - |
$2,327
63,013
kWh
|
- | - | |
03 | 2.7135: Install occupancy sensors | $230 | $95 |
$230
6,448
kWh
|
- | - | |
04 | 2.6218: Turn off equipment when not in use | $24 | - |
$24
586
kWh
|
- | - | |
05 | 2.2113: Repair or replace steam traps | $20,642 | $4,920 | - | - |
$20,642
-
MMBtu
|
|
06 | 2.4314: Use synthetic lubricant | $673 | $24 |
$673
15,240
kWh
|
- | - | |
TOTAL RECOMMENDED | $31,486 | $47,621 |
$9,588
257,327
kWh
|
$1,256
-
kW-mo/yr
|
$20,642
-
MMBtu
|
||
TOTAL IMPLEMENTED | $20,642 | $4,920 | - | - |
$20,642
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs