| Assessment Year | 1999 |
|---|---|
| Principal Product | Cat Litter |
| NAICS |
n/a
|
| SIC | 3298: |
| Sales Range | $5 M to 10M |
| # of Employees | 43 |
| Plant Area |
60,043
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $91,594 | 2,082,943 |
kWh
|
$0.044 |
| Electricity Demand | $44,436 | 5,646 |
kW-mo/yr
|
$7.87 |
| Electricity Fees | $(-1,667.0) | - |
|
- |
| LPG | $9,096 | 932 |
MMBtu
|
$9.76 |
| Wood | $194,472 | 118,571 |
MMBtu
|
$1.64 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $104,453 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Wood Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,888 | $13,066 |
$1,008
22,860
kWh
|
$880
-
kW-mo/yr
|
- | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,153 | $800 |
$2,153
48,945
kWh
|
- | - | - | |
| 03 | 2.2511: Insulate bare equipment | $8,350 | $30,000 | - | - |
$8,350
-
MMBtu
|
- | |
| 04 | 4.131: Modify process to reduce material use/cost | $92,062 | $180,000 | - | - | - | $92,062 | |
| TOTAL RECOMMENDED | $104,453 | $223,866 |
$3,161
71,805
kWh
|
$880
-
kW-mo/yr
|
$8,350
-
MMBtu
|
$92,062 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs