| Assessment Year | 1999 |
|---|---|
| Principal Product | Newspaper |
| NAICS |
n/a
|
| SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
| Sales Range | $100 M to 500M |
| # of Employees | 500 |
| Plant Area |
200,000
ft2
|
| Annual Production | 250,000,000
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $151,294 | 9,990,621 |
kWh
|
$0.015 |
| Electricity Demand | $278,798 | 19,972 |
kW-mo/yr
|
$13.96 |
| Electricity Fees | $48,770 | - |
|
- |
| Fuel Oil #2 | $51,321 | 12,743 |
MMBtu
|
$4.03 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $39,018 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,268 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,728 | $67,670 |
$7,764
514,361
kWh
|
$2,964
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.7135: Install occupancy sensors | $4,241 | $570 |
$4,241
88,511
kWh
|
- | - | - | - | - | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,063 | $2,063 |
$925
61,254
kWh
|
$1,138
-
kW-mo/yr
|
- | - | - | - | |
| 04 | 2.3191: Use demand controller or load shedder | $3,606 | $6,540 |
$1,163
131,301
kWh
|
$2,443
-
kW-mo/yr
|
- | - | - | - | |
| 05 | 2.1116: Improve combustion control capability | $1,540 | $3,000 | - | - |
$1,540
-
MMBtu
|
- | - | - | |
| 06 | 3.5316: Contract a wood pallet recycling company | $3,000 | - | - | - | - | - |
$3,000
-
lb
|
- | |
| 07 | 3.4145: Use magnetic technology to treat water | $1,840 | $3,500 | - | - | - |
$1,840
-
gal
|
- | - | |
| 08 | 4.521: Clear and rent existing space | $12,000 | - | - | - | - | - | - | $12,000 | |
| TOTAL RECOMMENDED | $39,018 | $83,343 |
$14,093
795,427
kWh
|
$6,545
-
kW-mo/yr
|
$1,540
-
MMBtu
|
$1,840
-
gal
|
$3,000
-
lb
|
$12,000 | ||
| TOTAL IMPLEMENTED | $12,268 | $70,670 |
$7,764
514,361
kWh
|
$2,964
-
kW-mo/yr
|
$1,540
-
MMBtu
|
- | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs