Assessment Year | 1998 |
---|---|
Principal Product | Prefabricated Wooden Trusses |
NAICS |
n/a
|
SIC | 2499: Wood Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
71,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,470
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $10,513 | 198,124 |
kWh
|
$0.053 |
Electricity Demand | $4,260 | 65 |
kW-mo/yr
|
$65.54 |
Electricity Fees | $15,110 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $252,505 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $246,500 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,685 | $5,673 |
$3,660
48,652
kWh
|
$1,025
-
kW-mo/yr
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $855 | $1,322 |
$634
7,620
kWh
|
$221
-
kW-mo/yr
|
- | |
03 | 2.7224: Reduce space conditioning during non-working hours | $465 | $420 |
$465
8,499
kWh
|
- | - | |
04 | 4.111: Add equipment/ operators to reduce production bottleneck | $246,500 | $180,480 | - | - | $246,500 | |
TOTAL RECOMMENDED | $252,505 | $187,895 |
$4,759
64,771
kWh
|
$1,246
-
kW-mo/yr
|
$246,500 | ||
TOTAL IMPLEMENTED | $246,500 | $180,480 | - | - | $246,500 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs