Assessment Year | 1998 |
---|---|
Principal Product | Industrial Mixing Equipment |
NAICS |
n/a
|
SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
Sales Range | $5 M to 10M |
# of Employees | 47 |
Plant Area |
40,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,015
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $22,067 | 505,276 |
kWh
|
$0.044 |
Electricity Demand | $24,540 | 1,992 |
kW-mo/yr
|
$12.32 |
Electricity Fees | $1,426 | - |
|
- |
Fuel Oil #2 | $3,704 | 695 |
MMBtu
|
$5.33 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,500 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,507 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,264 | $4,586 |
$969
18,757
kWh
|
$1,295
-
kW-mo/yr
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $45 | $132 |
$26
586
kWh
|
$19
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $198 | $400 |
$198
3,810
kWh
|
- | - | |
04 | 2.7224: Reduce space conditioning during non-working hours | $2,113 | $210 | - | - |
$2,113
-
MMBtu
|
|
05 | 2.7224: Reduce space conditioning during non-working hours | $880 | $420 |
$880
14,654
kWh
|
- | - | |
TOTAL RECOMMENDED | $5,500 | $5,748 |
$2,073
37,807
kWh
|
$1,314
-
kW-mo/yr
|
$2,113
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,507 | $5,118 |
$1,193
23,153
kWh
|
$1,314
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs