| Assessment Year | 1998 |
|---|---|
| Principal Product | Circuit Boards |
| NAICS |
n/a
|
| SIC | 2752: Commercial Printing, Lithographic |
| Sales Range | $1 M to 5M |
| # of Employees | 34 |
| Plant Area |
16,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 3,640
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $20,174 | 425,850 |
kWh
|
$0.047 |
| Electricity Demand | $10,923 | 1,976 |
kW-mo/yr
|
$5.53 |
| Electricity Fees | $5,722 | - |
|
- |
| Natural Gas | $4,242 | 541 |
MMBtu
|
$7.84 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,182 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,196 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,986 | $1,615 |
$3,737
78,839
kWh
|
$1,191
-
kW-mo/yr
|
$(-1,942.0)
-
MMBtu
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $925 | $2,175 |
$636
13,482
kWh
|
$289
-
kW-mo/yr
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $921 | $800 |
$921
19,343
kWh
|
- | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $95 | $91 |
$62
1,172
kWh
|
$33
-
kW-mo/yr
|
- | |
| 05 | 2.4314: Use synthetic lubricant | $255 | $255 |
$184
3,810
kWh
|
$71
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $5,182 | $4,936 |
$5,540
116,646
kWh
|
$1,584
-
kW-mo/yr
|
$(-1,942.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,196 | $3,321 |
$1,803
37,807
kWh
|
$393
-
kW-mo/yr
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs