| Assessment Year | 1998 |
|---|---|
| Principal Product | Threaded metal rods |
| NAICS |
n/a
|
| SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
| Sales Range | $10 M to 50M |
| # of Employees | 40 |
| Plant Area |
40,000
ft2
|
| Annual Production | 20,000,000
lb
|
| Production Hrs. Annual | 4,862
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $63,612 | 1,005,569 |
kWh
|
$0.063 |
| Electricity Demand | $18,734 | 2,058 |
kW-mo/yr
|
$9.10 |
| Electricity Fees | $(-1,257.0) | - |
|
- |
| Natural Gas | $30,663 | 5,237 |
MMBtu
|
$5.86 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,976 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,976 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,812 | $8,363 |
$4,162
65,651
kWh
|
$1,650
-
kW-mo/yr
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $6,307 | $10,032 |
$4,537
71,805
kWh
|
$1,770
-
kW-mo/yr
|
|
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,397 | $605 |
$1,266
3,810
kWh
|
$131
-
kW-mo/yr
|
|
| 04 | 2.7314: Reduce ventilation air | $1,460 | $1,100 |
$1,460
18,464
kWh
|
- | |
| TOTAL RECOMMENDED | $14,976 | $20,100 |
$11,425
159,730
kWh
|
$3,551
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $14,976 | $20,100 |
$11,425
159,730
kWh
|
$3,551
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs