| Assessment Year | 1997 |
|---|---|
| Principal Product | fabrics |
| NAICS |
n/a
|
| SIC | 2211: Broadwoven Fabric Mills, Cotton |
| Sales Range | $10 M to 50M |
| # of Employees | 127 |
| Plant Area |
84,000
ft2
|
| Annual Production | 5,400,000
thousand feet
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $34,609 | 1,582,063 |
kWh
|
$0.022 |
| Electricity Demand | $43,411 | 3,653 |
kW-mo/yr
|
$11.88 |
| Electricity Fees | $7,887 | - |
|
- |
| LPG | $8,206 | 1,044 |
MMBtu
|
$7.86 |
| Fuel Oil #4 | $14,418 | 3,655 |
MMBtu
|
$3.94 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $120,672 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #4 Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,532 | $3,048 | n/a |
$1,213
55,393
kWh
|
$1,319
-
kW-mo/yr
|
- | - | - |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,568 | $589 | n/a |
$1,568
71,512
kWh
|
- | - | - | - |
| 03 | 2.2437: Recover waste heat from equipment | $1,915 | $1,750 | n/a | - | - |
$1,915
-
MMBtu
|
- | - |
| 04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,962 | $1,495 | n/a | - | - |
$1,962
-
MMBtu
|
- | - |
| 05 | 2.4133: Use most efficient type of electric motors | $1,327 | $2,285 | n/a |
$638
29,015
kWh
|
$689
-
kW-mo/yr
|
- | - | - |
| 06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $6,000 | - | n/a | - | - | - |
$6,000
-
lb
|
- |
| 07 | 3.5313: Increase amount of waste recovered for resale | $5,368 | - | n/a | - | - | - |
$5,368
-
lb
|
- |
| 08 | 4.511: Expand operations into unused space | $100,000 | $51,000 | n/a | - | - | - | - | $100,000 |
| TOTAL RECOMMENDED | $120,672 | $60,167 |
$3,419
155,920
kWh
|
$2,008
-
kW-mo/yr
|
$3,877
-
MMBtu
|
$11,368
-
lb
|
$100,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #4 Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs