ITAC Assessment: OD0075
ITAC logo
ITAC Assessment: OD0075
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Yarn and fabric
NAICS
n/a
SIC 2211: Broadwoven Fabric Mills, Cotton
Sales Range $50
M
to 100
M
# of Employees 432
Plant Area 371,309
ft2
Annual Production 70,750,000
lb
Production Hrs. Annual 8,400
hrs
Location (State) Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $712,534 43,926,144
kWh
Electricity Demand $950,401 141,208
kW-mo/yr
Electricity Fees $189,215 -
Fuel Oil #6 $1,861,104 504,756
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $104,954 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $56,858

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Fuel Oil #6 Savings By-product Production Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $21,911 $1,400 - - $21,911
-
MMBtu
-
02 2.2414: Use waste heat from hot flue gases to preheat $13,096 $5,800 - - $13,096
-
MMBtu
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $22,546 $51,404 $14,369
886,870
kWh
$8,177
-
kW-mo/yr
- -
04 2.2612: Use cooling tower water instead of refrigeration $4,186 $5,691 $2,833
144,783
kWh
$1,353
-
kW-mo/yr
- -
05 2.4133: Use most efficient type of electric motors $5,775 $19,955 $3,588
221,571
kWh
$2,187
-
kW-mo/yr
- -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,440 $3,111 $1,531
94,666
kWh
$909
-
kW-mo/yr
- -
07 3.5313: Increase amount of waste recovered for resale $35,000 - - - - $35,000
TOTAL RECOMMENDED $104,954 $87,361 $22,321
1,347,890
kWh
$12,626
-
kW-mo/yr
$35,007
-
MMBtu
$35,000
TOTAL IMPLEMENTED $56,858 $81,561 $22,321
1,347,890
kWh
$12,626
-
kW-mo/yr
$21,911
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Fuel Oil #6 Savings By-product Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs