Assessment Year | 1996 |
---|---|
Principal Product | Textile Processing |
NAICS |
n/a
|
SIC | 2463: |
Sales Range | $10 M to 50M |
# of Employees | 185 |
Plant Area |
102,000
ft2
|
Annual Production | 90,000
thousand feet
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $116,871 | 6,091,442 |
kWh
|
$0.019 |
Electricity Demand | $162,105 | 13,764 |
kW-mo/yr
|
$11.78 |
Electricity Fees | $31,855 | - |
|
- |
Natural Gas | $292,146 | 89,580 |
MMBtu
|
$3.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,141 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $6,883 | $12,945 |
$3,403
177,315
kWh
|
$3,480
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,972 | $6,824 |
$1,616
84,701
kWh
|
$2,356
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,832 | $600 |
$2,832
147,421
kWh
|
- | - | - | |
04 | 2.2211: Use optimum temperature | $6,054 | - | - | - |
$6,054
-
MMBtu
|
- | |
05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,400 | - | - | - | - |
$2,400
-
lb
|
|
TOTAL RECOMMENDED | $22,141 | $20,369 |
$7,851
409,437
kWh
|
$5,836
-
kW-mo/yr
|
$6,054
-
MMBtu
|
$2,400
-
lb
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs