Assessment Year | 1996 |
---|---|
Principal Product | Softboard sheathing |
NAICS |
n/a
|
SIC | 2499: Wood Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 122 |
Plant Area |
200,000
ft2
|
Annual Production | 240,000
thousand feet
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $990,943 | 58,804,807 |
kWh
|
$0.017 |
Electricity Demand | $1,389,833 | 224,337 |
kW-mo/yr
|
$6.20 |
Electricity Fees | $86,122 | - |
|
- |
Coal | $536,369 | 489,188 |
MMBtu
|
$1.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $472,755 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $5,023 | $11,843 |
$3,324
196,659
kWh
|
$1,699
-
kW-mo/yr
|
- | - | - | |
02 | 4.114: Add/modify equipment to improve drying process | $308,827 | $235,200 |
$(-113,522.0)
(-6,717,468)
kWh
|
$(-55,651.0)
-
kW-mo/yr
|
- | $(-2,000.0) | $480,000 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,695 | $24,130 |
$8,266
489,156
kWh
|
$5,429
-
kW-mo/yr
|
- | - | - | |
04 | 2.7132: Install timers on light switches in little used areas | $3,454 | $639 |
$3,454
204,279
kWh
|
- | - | - | - | |
05 | 2.3134: Shift from daytime to nighttime operation | $124,620 | $208,110 | - |
$124,620
-
kW-mo/yr
|
- | - | - | |
06 | 3.5313: Increase amount of waste recovered for resale | $17,136 | - | - | - |
$17,136
-
lb
|
- | - | |
TOTAL RECOMMENDED | $472,755 | $479,922 |
$(-98,478.0)
(-5,827,374)
kWh
|
$76,097
-
kW-mo/yr
|
$17,136
-
lb
|
$(-2,000.0) | $480,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs