| Assessment Year | 1995 |
|---|---|
| Principal Product | Measuring and Controlling Devices, NEC |
| NAICS |
n/a
|
| SIC | 3829: Measuring and Controlling Devices, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 100 |
| Plant Area |
42,400
ft2
|
| Annual Production | 35,611
pieces
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $95,568 | 1,436,694 |
kWh
|
$0.067 |
| Natural Gas | $3,745 | 622 |
MMBtu
|
$6.02 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,157 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7224: Reduce space conditioning during non-working hours | $1,291 | - | - |
$1,291
-
MMBtu
|
|
| 02 | 2.1134: Eliminate leaks in combustible gas lines | $426 | - | - |
$426
-
MMBtu
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $1,660 | $3,096 |
$1,660
24,033
kWh
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $299 | $619 |
$299
4,103
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,971 | $11,838 |
$3,971
59,789
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $241 | $270 |
$241
4,103
kWh
|
- | |
| 07 | 2.7122: Disconnect ballasts | $269 | - |
$269
3,810
kWh
|
- | |
| TOTAL RECOMMENDED | $8,157 | $15,823 |
$6,440
95,838
kWh
|
$1,717
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs