Assessment Year | 2000 |
---|---|
Principal Product | Lime Products |
NAICS |
n/a
|
SIC | 3274: Lime |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
n/a
|
Annual Production | 600,000
ton
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $381,439 | 7,307,151 |
kWh
|
$0.052 |
Electricity Demand | $260,830 | 23,817 |
kW-mo/yr
|
$10.95 |
Electricity Fees | $(-20,813.0) | - |
|
- |
LPG | $40,779 | 4,384 |
MMBtu
|
$9.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,302 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,244 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | LPG Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1116: Improve combustion control capability | $3,058 | $5,650 | - | - | - |
$3,058
-
MMBtu
|
|
02 | 2.3212: Optimize plant power factor | $12,568 | $9,490 |
$7,260
116,647
kWh
|
- | $5,308 | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $676 | $200 |
$140
2,638
kWh
|
$524
-
kW-mo/yr
|
$12 | - | |
TOTAL RECOMMENDED | $16,302 | $15,340 |
$7,400
119,285
kWh
|
$524
-
kW-mo/yr
|
$5,320 |
$3,058
-
MMBtu
|
||
TOTAL IMPLEMENTED | $13,244 | $9,690 |
$7,400
119,285
kWh
|
$524
-
kW-mo/yr
|
$5,320 | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs