Assessment Year 2000
Principal Product Clay and Earthen Fillers
NAICS
n/a
SIC 3255: Clay Refractories
Sales Range $1
M
to 5
M
# of Employees 20
Plant Area 362,111
ft2
Annual Production 24,000
ton
Production Hrs. Annual 3,430
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $49,856 824,736
kWh
Electricity Demand $27,257 3,936
kW-mo/yr
Electricity Fees $3,042 -
Natural Gas $45,282 8,377
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,068 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $28,056

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings
01 2.4133: Use most efficient type of electric motors $2,327 $7,833 $1,374
23,154
kWh
$889
-
kW-mo/yr
$64 - - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $959 $500 $593
9,965
kWh
$341
-
kW-mo/yr
$25 - - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $171 $63 $133
2,345
kWh
$33
-
kW-mo/yr
$5 - - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,656 $5,920 $1,292
21,981
kWh
$320
-
kW-mo/yr
$44 - - -
05 2.7231: Use radiant heater for spot heating $4,012 $10,869 - $2,502
-
kW-mo/yr
$953 $557
-
MMBtu
- -
06 4.441: Install automatic packing equipment $21,000 $78,000 - - - - - $21,000
07 3.5313: Increase amount of waste recovered for resale $1,943 $3,500 - - - - $1,943
-
lb
-
TOTAL RECOMMENDED $32,068 $106,685 $3,392
57,445
kWh
$4,085
-
kW-mo/yr
$1,091 $557
-
MMBtu
$1,943
-
lb
$21,000
TOTAL IMPLEMENTED $28,056 $95,816 $3,392
57,445
kWh
$1,583
-
kW-mo/yr
$138 - $1,943
-
lb
$21,000
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs