Assessment Year | 2000 |
---|---|
Principal Product | Moulded Wood Products |
NAICS |
n/a
|
SIC | 2431: Millwork |
Sales Range | $5 M to 10M |
# of Employees | 25 |
Plant Area |
68,000
ft2
|
Annual Production | 3,180,709
units
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $23,784 | 293,376 |
kWh
|
$0.081 |
Electricity Demand | $8,332 | 1,994 |
kW-mo/yr
|
$4.18 |
Electricity Fees | $959 | - |
|
- |
LPG | $2,457 | 248 |
MMBtu
|
$9.91 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $2,741 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,249 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $494 | $196 |
$359
4,396
kWh
|
$134
-
kW-mo/yr
|
$1 | - | |
02 | 2.4133: Use most efficient type of electric motors | $1,042 | $2,074 |
$753
9,379
kWh
|
$288
-
kW-mo/yr
|
$1 | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $207 | - |
$107
1,172
kWh
|
$100
-
kW-mo/yr
|
- | - | |
04 | 3.5313: Increase amount of waste recovered for resale | $998 | $3,500 | - | - | - |
$998
-
lb
|
|
TOTAL RECOMMENDED | $2,741 | $5,770 |
$1,219
14,947
kWh
|
$522
-
kW-mo/yr
|
$2 |
$998
-
lb
|
||
TOTAL IMPLEMENTED | $1,249 | $2,074 |
$860
10,551
kWh
|
$388
-
kW-mo/yr
|
$1 | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs