Assessment Year | 1997 |
---|---|
Principal Product | Concrete |
NAICS |
n/a
|
SIC | 3273: Ready-Mixed Concrete |
Sales Range | $5 M to 10M |
# of Employees | 18 |
Plant Area |
n/a
|
Annual Production | 500,000
ton
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $137,639 | 1,267,878 |
kWh
|
$0.11 |
Electricity Demand | $22,071 | 23,571 |
kW-mo/yr
|
$0.94 |
Electricity Fees | $3,930 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,719 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $246 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7134: Use photocell controls | $246 | $120 |
$233
3,810
kWh
|
$13
-
kW-mo/yr
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $7,226 | $6,404 |
$6,878
38,394
kWh
|
$348
-
kW-mo/yr
|
- | |
03 | 2.3212: Optimize plant power factor | $1,247 | $3,460 | - | - | $1,247 | |
TOTAL RECOMMENDED | $8,719 | $9,984 |
$7,111
42,204
kWh
|
$361
-
kW-mo/yr
|
$1,247 | ||
TOTAL IMPLEMENTED | $246 | $120 |
$233
3,810
kWh
|
$13
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs