Assessment Year | 1997 |
---|---|
Principal Product | Prunes |
NAICS |
n/a
|
SIC | 2034: Dried and Dehydrated Fruits, Vegetables, and Soup Mixes |
Sales Range | $1 M to 5M |
# of Employees | 60 |
Plant Area |
150,000
ft2
|
Annual Production | 18,610
ton
|
Production Hrs. Annual | 3,434
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $53,734 | 608,441 |
kWh
|
$0.088 |
Electricity Demand | $14,732 | 2,203 |
kW-mo/yr
|
$6.69 |
Electricity Fees | $1,043 | - |
|
- |
Natural Gas | $111,146 | 54,648 |
MMBtu
|
$2.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,210 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,210 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $9,086 | $58,500 | - | - |
$9,086
-
MMBtu
|
|
02 | 2.7124: Make a practice of turning off lights when not needed | $124 | - |
$97
1,172
kWh
|
$27
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $9,210 | $58,500 |
$97
1,172
kWh
|
$27
-
kW-mo/yr
|
$9,086
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,210 | $58,500 |
$97
1,172
kWh
|
$27
-
kW-mo/yr
|
$9,086
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs