Assessment Year | 1997 |
---|---|
Principal Product | Ink |
NAICS |
n/a
|
SIC | 2893: Printing Ink |
Sales Range | $10 M to 50M |
# of Employees | 32 |
Plant Area |
30,000
ft2
|
Annual Production | 638,000
lb
|
Production Hrs. Annual | 2,730
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $33,621 | 765,240 |
kWh
|
$0.044 |
Electricity Demand | $33,292 | 3,648 |
kW-mo/yr
|
$9.13 |
Electricity Fees | $1,338 | - |
|
- |
Natural Gas | $12,139 | 2,427 |
MMBtu
|
$5.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,692 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,946 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,052 | $840 |
$1,072
24,326
kWh
|
$980
-
kW-mo/yr
|
- | - | - | - | - | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $1,562 | $375 |
$816
18,464
kWh
|
$746
-
kW-mo/yr
|
- | - | - | - | - | - | |
03 | 2.7135: Install occupancy sensors | $789 | $410 |
$500
11,430
kWh
|
$289
-
kW-mo/yr
|
- | - | - | - | - | - | |
04 | 2.4133: Use most efficient type of electric motors | $258 | $308 |
$113
2,638
kWh
|
$145
-
kW-mo/yr
|
- | - | - | - | - | - | |
05 | 2.2511: Insulate bare equipment | $431 | $1,035 |
$431
25,498
kWh
|
- | - | - | - | - | - | - | |
06 | 2.2211: Use optimum temperature | $195 | - | - | - |
$195
-
MMBtu
|
- | - | - | - | - | |
07 | 2.2311: Heat treat parts only to required specifications or standards | $102 | - |
$10
293
kWh
|
$7
-
kW-mo/yr
|
$85
-
MMBtu
|
- | - | - | - | - | |
08 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $450 | $690 |
$121
2,638
kWh
|
$110
-
kW-mo/yr
|
$219
-
MMBtu
|
- | - | - | - | - | |
09 | 3.1191: Change procedures / equipment / operating conditions | $920 | $150 |
$645
14,947
kWh
|
- |
$275
-
MMBtu
|
- | - | - | - | - | |
10 | 3.8141: Regenerate cleaning solvent on-site and reuse | $3,712 | $5,025 |
$(-18.0)
(-293)
kWh
|
- | - | - | - |
$3,730
-
gal
|
- | - | |
11 | 3.5313: Increase amount of waste recovered for resale | $78 | - | - | - | - | - | - | - |
$78
-
lb
|
- | |
12 | 2.3132: Recharge batteries on during off-peak demand periods | $394 | $147 | - | - | - | - | - | - | - | $394 | |
13 | 3.4116: Meter recycled water (to reduce sewer charges) | $437 | $120 | - | - | - |
$437
-
Tgal
|
- | - | - | - | |
14 | 3.5313: Increase amount of waste recovered for resale | $312 | - | - | - | - | - |
$312
-
gal
|
- | - | - | |
TOTAL RECOMMENDED | $11,692 | $9,100 |
$3,690
99,941
kWh
|
$2,277
-
kW-mo/yr
|
$774
-
MMBtu
|
$437
-
Tgal
|
$312
-
gal
|
$3,730
-
gal
|
$78
-
lb
|
$394 | ||
TOTAL IMPLEMENTED | $3,946 | $2,675 |
$1,491
49,531
kWh
|
$1,008
-
kW-mo/yr
|
$304
-
MMBtu
|
$437
-
Tgal
|
$312
-
gal
|
- | - | $394 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |