Assessment Year | 1996 |
---|---|
Principal Product | Water-Base Adhesives |
NAICS |
n/a
|
SIC | 2891: Adhesives and Sealants |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
57,600
ft2
|
Annual Production | 65,000,000
ton
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $161,621 | 3,362,837 |
kWh
|
$0.048 |
Electricity Demand | $42,184 | 7,083 |
kW-mo/yr
|
$5.96 |
Natural Gas | $103,940 | 19,756 |
MMBtu
|
$5.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,434 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,181 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $385 | $225 |
$342
7,034
kWh
|
$43
-
kW-mo/yr
|
- | - | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $864 | $200 |
$720
14,947
kWh
|
$144
-
kW-mo/yr
|
- | - | - | |
03 | 2.6218: Turn off equipment when not in use | $2,822 | - |
$2,107
43,669
kWh
|
$715
-
kW-mo/yr
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,545 | $200 |
$1,545
32,239
kWh
|
- | - | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $387 | $200 |
$312
51,876
kWh
|
$75
-
kW-mo/yr
|
- | - | - | |
06 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $12,900 | $3,600 | - | - |
$12,900
-
MMBtu
|
- | - | |
07 | 3.8121: Cover containers to minimize evaporative losses | $4,531 | $7,000 | - | - |
$282
-
MMBtu
|
$37
-
Tgal
|
$4,212 | |
TOTAL RECOMMENDED | $23,434 | $11,425 |
$5,026
149,765
kWh
|
$977
-
kW-mo/yr
|
$13,182
-
MMBtu
|
$37
-
Tgal
|
$4,212 | ||
TOTAL IMPLEMENTED | $3,181 | $825 |
$2,919
106,096
kWh
|
$262
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs