ITAC Assessment: NV0074
ITAC logo
ITAC Assessment: NV0074
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Water-Base Adhesives
NAICS
n/a
SIC 2891: Adhesives and Sealants
Sales Range $10
M
to 50
M
# of Employees 60
Plant Area 57,600
ft2
Annual Production 65,000,000
ton
Production Hrs. Annual 7,488
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $161,621 3,362,837
kWh
Electricity Demand $42,184 7,083
kW-mo/yr
Natural Gas $103,940 19,756
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $23,434 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,181

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Primary Product Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $385 $225 $342
7,034
kWh
$43
-
kW-mo/yr
- - -
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $864 $200 $720
14,947
kWh
$144
-
kW-mo/yr
- - -
03 2.6218: Turn off equipment when not in use $2,822 - $2,107
43,669
kWh
$715
-
kW-mo/yr
- - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,545 $200 $1,545
32,239
kWh
- - - -
05 2.4133: Use most efficient type of electric motors $387 $200 $312
51,876
kWh
$75
-
kW-mo/yr
- - -
06 2.2449: Recover heat from exhausted steam, hot air or hot water $12,900 $3,600 - - $12,900
-
MMBtu
- -
07 3.8121: Cover containers to minimize evaporative losses $4,531 $7,000 - - $282
-
MMBtu
$37
-
Tgal
$4,212
TOTAL RECOMMENDED $23,434 $11,425 $5,026
149,765
kWh
$977
-
kW-mo/yr
$13,182
-
MMBtu
$37
-
Tgal
$4,212
TOTAL IMPLEMENTED $3,181 $825 $2,919
106,096
kWh
$262
-
kW-mo/yr
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs