| Assessment Year | 1996 |
|---|---|
| Principal Product | Firelogs |
| NAICS |
n/a
|
| SIC | 2499: Wood Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 24 |
| Plant Area |
45,000
ft2
|
| Annual Production | 2,000,000
units
|
| Production Hrs. Annual | 2,185
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $41,084 | 601,700 |
kWh
|
$0.068 |
| Electricity Demand | $30,150 | 3,970 |
kW-mo/yr
|
$7.59 |
| Electricity Fees | $215 | - |
|
- |
| Natural Gas | $59,444 | 9,795 |
MMBtu
|
$6.07 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $259,837 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $251,339 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $8,498 | $(-2,645.0) |
$8,374
118,113
kWh
|
$124
-
kW-mo/yr
|
- | - | |
| 02 | 2.2511: Insulate bare equipment | $20,608 | $2,945 | - | - |
$20,608
-
MMBtu
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $731 | $200 |
$731
10,844
kWh
|
- | - | - | |
| 04 | 4.113: Install refrigeration system to cool product | $230,000 | $40,000 | - | - | - | $230,000 | |
| TOTAL RECOMMENDED | $259,837 | $40,500 |
$9,105
128,957
kWh
|
$124
-
kW-mo/yr
|
$20,608
-
MMBtu
|
$230,000 | ||
| TOTAL IMPLEMENTED | $251,339 | $43,145 |
$731
10,844
kWh
|
- |
$20,608
-
MMBtu
|
$230,000 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs