Assessment Year | 1996 |
---|---|
Principal Product | Plastic Signs |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 14 |
Plant Area |
30,000
ft2
|
Annual Production | 1,200
pieces
|
Production Hrs. Annual | 4,862
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $9,715 | 207,796 |
kWh
|
$0.047 |
Electricity Demand | $19,776 | 3,883 |
kW-mo/yr
|
$5.09 |
Electricity Fees | $1,400 | - |
|
- |
Natural Gas | $1,321 | 207 |
MMBtu
|
$6.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,089 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,658 | $2,000 | n/a | - | - | - | $2,658 |
02 | 2.7144: Install spectral reflectors / delamp | $814 | $60 | n/a |
$545
11,723
kWh
|
$269
-
kW-mo/yr
|
- | - |
03 | 2.7135: Install occupancy sensors | $511 | $56 | n/a |
$357
5,569
kWh
|
$154
-
kW-mo/yr
|
- | - |
04 | 2.4321: Upgrade obsolete equipment | $11,766 | $33,000 | n/a |
$11,766
72,098
kWh
|
- | - | - |
05 | 3.6192: Use a less expensive method of waste removal | $2,340 | - | n/a | - | - | $2,340 | - |
TOTAL RECOMMENDED | $18,089 | $35,116 |
$12,668
89,390
kWh
|
$423
-
kW-mo/yr
|
$2,340 | $2,658 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs